Excellent turn-key project for clean room company supplier: Air filter refers to the air filter device, which is generally used in clean workshop, clean workshop, laboratory and clean room, or used for dust prevention of electronic machinery communication equipment. There are primary filter, medium efficiency filter, high efficiency filter and sub high efficiency model. Different models have different standards and performance. The comprehensive performance test of clean room includes: Wind speed, air volume (ventilation frequency), temperature and relative humidity, suspended particle number, planktonic bacteria, settling bacteria, static pressure difference, illumination, noise, air flow pattern, self purification time, high-efficiency filter leak detection, total bacterial colonies in the air, total bacterial colonies on the surface of the worktable, total bacterial colonies on the surface of the worktable, total bacterial colonies on the surface of workers’ hands, etc. Read more info at pharma turnkey projects.

The detection of air volume and wind speed must be carried out first, and all effects of purified air conditioning must be obtained under the designed air volume and wind speed. Before air volume detection, it is necessary to check whether the fan operates normally, whether all components in the system are installed correctly and whether there are obstacles (such as whether the filter is blocked or blocked). All valves should be fixed at a certain opening position, and the size of the measured air outlet and air duct must be measured. For the turbulent flow clean room, the air supply volume shall be determined by the air outlet method or air duct method. See Item 6, 7 and 8 respectively. For the air outlet without filter, the method in Appendix I of the current national standard code for construction and acceptance of ventilation and air conditioning engineering (gbj243) can be implemented.

Pharma clean room supplier from sz-pharma.com: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.

The clean room is generally made of foam color steel or rock wool board with a vertical wall and an independent air-conditioning air supply system. The air is filtered through high-efficiency three-stage filtration in junior high schools. The personnel and materials are equipped with an air shower room and a transfer window for clean filtration.

The above introduction is related to the introduction of clean room and testing purpose.If you have different opinions or suggestions, you can always contact us.As long as you want the clean room project, Suzhou Pharma Machinery Co., Ltd. will realize it for you.Choose a reliable engineering company, Suzhou Pharma Machinery Co., Ltd., will be responsible for your project to the end, and the reputation is guaranteed.Our company has completed 500+ clean room projects all over the world. Many new and old customers like to buy the products they want in our company. The price is reasonable, the integrity is guaranteed, and the after-sales service is good.If you have related (clean room) projects recently, you can contact us at any time. Discover additional details at https://www.sz-pharma.com/.

Labeller is a device that pastes rolled self-adhesive paper labels (paper or metal foil) onto PCB, products or specified packaging. It has a wide range of applications, and can meet the full circle labeling or semi circle labeling of round bottles. The labeling switching between bottles is simple and easy to adjust. Blister packaging machine is a machine that uses transparent plastic film or sheet to form a blister and seals the product between the blister and the bottom plate by means of heat sealing and bonding. Application: capsule, plain tablet, sugar coating, capsule, injection, abnormity, etc., as well as sealed packaging of medical devices, light food, electronic components blister.

Efficiency of Equipment: Some equipment, such as electronics and mechanical components, require specific humidity levels to function correctly. Maintaining the right humidity levels in clean rooms ensures optimal performance and longevity of these critical pieces of equipment. How to Maintain Optimal Humidity Levels in Clean Rooms? To maintain optimal humidity levels in clean rooms, consider the following steps: Install a Dehumidifier: A dehumidifier is an essential tool for maintaining proper humidity levels in clean rooms. It removes excess moisture from the air, keeping humidity levels within the desired range. Choose a dehumidifier based on the size of your clean room and the relative humidity requirements you need to meet.

Cleanroom workshop take the control of inanimate particles as the object. Mainly control the pollution of the living objects with living particles to the outside situation and people. The negative pressure inside the atmosphere must be maintained. it’s suitable for bacteriology, biology, clean laboratory, physical engineering, recombinant genes, vaccine preparation. In order to know your requirement, please fill the following table carefully and supply CAD layout, so that we can provide correct scheme and quotation, thank you!