Top rated slitting line manufacturer factory: How to deal with the failure of the main transformer cooler? The failure of the main transformer cooler may cause the temperature of the main transformer to rise, thereby affecting the normal operation of the transformer. Therefore, if it is found that the main transformer cooler is faulty, it is necessary to take timely measures to deal with it. Here are some possible approaches: Replacing Faulty Cooler Parts: If some parts in your cooler are damaged or malfunctioning, consider replacing those parts to restore the cooler to working properly. The specific operation needs to be carried out according to the structure of the cooler and the cause of the failure. Clean the cooler: If the pipes or cooling fins in the cooler are clogged or dirt accumulates, it may reduce the cooling effect and affect the normal operation of the transformer. The way of cleaning can be used to remove the dirt and sundries inside the cooler to restore the normal operation of the cooler. Read more info at https://www.canwindg.com/products-20760.

What is eddy current? What are the disadvantages of eddy current generation? Eddy current refers to a kind of current generated in the conductor, which is the induced current caused by the change of the magnetic field. The eddy current forms a circular current flow path in the conductor, and this current forms a motion state similar to an eddy current inside the conductor, so it is called an eddy current. The generation of eddy currents has the following disadvantages: Energy loss: Eddy currents create circular currents in conductors, which generate heat as they flow continuously in conductors. Since the generation of eddy currents is caused by changes in the magnetic field, in equipment such as transformers and motors.

Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.

The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.

A transformer core is a static device that provides a channel for magnetic flux to flow in a transformer. The core is constructed using thin strips of silicone steel. The silicon steel sheets are electrically isolated and coupled to reduce no-load losses in the transformer.The core of a transformer is made of soft iron. Transformers are used in various fields like power generation grid, distribution sector, transmission, and electric energy consumption.

Founded in 2002, CANWIN Automatic Equipment Manufacturing Co., Ltd. is one of the largest electrical equipment manufacturers in China. We focus on the R&D for Silicon Steel Sheet Cut To Length Lines, Silicon Steel Sheet Slitting Line, Transformer Foil Winding Machines and other equipment. Adhering to the business route of High-end Manufacturing+ Smart Equipment + Smart Factory, we established the Silicon Steel Sheet Engineering Technology Research Center, Metal Strip Precision Cutting Key Technology & Equipment Engineering Center, and Power Transformer Intelligent Manufacturing Center to improve the shearing precision and speed. We have contributed the upgrading and innovating of global power industry institutions.

The materials that can be processed by longitudinal shear equipment include cold-rolled plate, stainless steel plate, aluminum plate, galvanized plate and color coated plate. However, for different materials, there are certain differences in the strength of blade materials, so as to obtain good cutting effect. Canwin slitting line supplier & manufacturer focus on the internal management and opens up the market.We continuously achieve development in the competition based on strong technical capability, high-quality products, and comprehensive and thoughtful services.

As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. See even more information at canwindg.com

As a professional energy storage system manufacturer, Canwin specialized in battery energy storage system and containerized energy storage system manufacturing. An energy storage system, often abbreviated as ESS, is a device or group of devices assembled together, capable of storing energy in order to supply electrical energy at a later time. In the energy storage systems, the lithium energy storage battery only interacts with the energy storage converter at high voltage, and the converter takes power from the AC grid to charge the battery pack. Or the battery pack supplies power to the converter, and the electric energy is converted into AC by the converter and sent to the AC power grid.

To accommodate the needs of grid voltage changes, the high-voltage side of the transformer has taps, which can be adjusted by adjusting the number of turns in the high-voltage winding to regulate the output voltage on the low-voltage side. Rated current (A): The current allowed to pass through the transformer for a long time under rated capacity. No-load loss (kW): The active power drawn when a rated voltage at rated frequency is applied to one winding terminal and the remaining windings are open circuit.It is related to the performance and manufacturing process of the core silicon steel sheet, as well as the applied voltage.

Power Quality and Distribution Transformers – The efficiency of distribution transformer substations is significantly affected by power quality. These transformers, which are critical components of the electrical distribution system, convert high-voltage electricity into lower voltage levels suitable for end-use applications. The performance and efficiency of these transformers largely depend on the quality of power they receive. Poor power quality, characterized by voltage sags, swells, harmonics, and flicker, can lead to increased losses in power distribution transformers. These losses can be categorized into two types: core losses and copper losses. Core losses occur due to variations in the magnetic field within the transformer’s core, while copper losses occur due to the resistance of the transformer’s windings. Both these losses are exacerbated under conditions of poor power quality, leading to decreased efficiency of the transformer.