Slitting line machine supplier by Canwin: When these harmonic currents flow through a transformer, they can cause increased core losses due to hysteresis and eddy currents. Hysteresis loss is related to the magnetization and demagnetization of the transformer’s core material in response to the alternating current. Eddy current loss occurs when induced currents circulate within the core material, creating local magnetic fields that oppose the main field. Both these losses increase with the frequency of the current. Thus, higher frequency harmonic currents can lead to considerably higher core losses, reducing the transformer’s efficiency and causing it to overheat, which can shorten its lifespan. See more information at https://www.canwindg.com/products-detail-127763.

Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference.

Adopt energy-saving measures: During the operation of the transformer, energy-saving measures can be adopted, such as adopting a high-efficiency cooling system, reducing the load rate of the transformer, optimizing the operation scheduling of the transformer, etc., to reduce energy loss and improve efficiency. Regular maintenance and overhaul: Regular maintenance and overhaul of transformers can maintain the normal operation and stability of transformers, thereby reducing energy loss and improving performance. Choose the appropriate transformer connection method: Different connection methods of the transformer will also affect the performance of the transformer. When choosing a transformer connection method, the optimal connection method can be selected according to actual needs and load characteristics to improve efficiency. To sum up, improving transformer efficiency can be achieved by optimizing design, selecting high-quality materials, adopting energy-saving measures, regular maintenance and overhaul, and selecting appropriate connection methods. In practical applications, various factors need to be considered comprehensively to select the most suitable method for improving performance.

The company mainly produces 150 model oil-type transformercore shearing equipment below 1 600KVA, 300 model dry type transformer core shearing equipment below 6300KVA, 400 model special transformer core shearing equipment below 12500KVA and 600 model special transformer core shearing equipment below 63000KVA. 800 model extra transformer core shearing equipment, 1000 model extra transformer core shearing equipment, the type 1250 model CRGsilicon steel CNC slitting machine, and the dry type transformer core under 110KV automatic cutting and laminated processing center, oil transformer core automatic cutting robot automatic lamination processing center, reactor cutting center below 35Kv, 220KV high voltage transformer tc. CANWIN hire famous designer in Europe as our senior consultant, and germany Siemens as our strategic partner. The products have formed 5 series and more than 50 specifications.

The materials that can be processed by longitudinal shear equipment include cold-rolled plate, stainless steel plate, aluminum plate, galvanized plate and color coated plate. However, for different materials, there are certain differences in the strength of blade materials, so as to obtain good cutting effect. Canwin slitting line supplier & manufacturer focus on the internal management and opens up the market.We continuously achieve development in the competition based on strong technical capability, high-quality products, and comprehensive and thoughtful services.

The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.

A transformer core is a static device that provides a channel for magnetic flux to flow in a transformer. The core is constructed using thin strips of silicone steel. The silicon steel sheets are electrically isolated and coupled to reduce no-load losses in the transformer.The core of a transformer is made of soft iron. Transformers are used in various fields like power generation grid, distribution sector, transmission, and electric energy consumption.

The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. Discover additional details at canwindg.com

The metal laser cutting machine focuses the laser emitted from the laser into a laser beam with high power density through the optical path system. The laser beam irradiates the surface of the workpiece to make the workpiece reach the melting point or boiling point. At the same time, the high-pressure gas coaxial with the beam blows away the molten or gasified metal. With the movement of the relative position between the beam and the workpiece, the material will finally form a slit, so as to achieve the purpose of cutting. Laser cutting process uses invisible light beam to replace the traditional mechanical knife. It has the characteristics of high precision, fast cutting, not limited to the limitation of cutting pattern, automatic typesetting, material saving, smooth incision and low processing cost. It will gradually improve or replace the traditional metal cutting process equipment.Want to konw more about metal cutting machine, contact us, one of the most professional metal laser cutting machine manufacturers & suppliers in China.

Digital measurement – Digital measurement of transformers or other components can be conducted, and the measurement results can be called and collected from the process layer and station control layer through digital networks, thus monitoring transformers and other equipment.Status visualization – The operation status of transformers can be visualized and observed in the power grid.Smart grid or other related systems can express the status information of transformer self-detection or information interaction.

Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.